For differential pressure and flow
| 
               SITRANS P500 for differential pressure and flow  | 
          ||
|---|---|---|
| 
               Input  | 
            ||
| 
               Measured variable  | 
            
               Differential pressure and flow  | 
          |
| 
               Span (infinitely adjustable)  | 
            
               Measuring span  | 
            
               Maximum operating pressure  | 
          
| 
               1,25 ... 250 mbar  | 
            
               160 bar (2320 psi)  | 
          |
| 
               6,25 ... 1250 mbar  | 
          ||
| 
               Lower measuring limit  | 
            ||
              
  | 
            
               100% of max. span and/or 30 mbar a (0.44 psi a)  | 
          |
| 
               Upper measuring limit  | 
            
               100% of max. span  | 
          |
| 
               Start of scale  | 
            
               Between measuring limits (infinitely adjustable)  | 
          |
| 
               Output  | 
            ||
| 
               Output signal  | 
            
               4 ... 20 mA  | 
          |
              
  | 
            
               3.55 mA, factory preset to 3.8 mA  | 
          |
              
  | 
            
               23 mA, factory setting 20.5 mA  | 
          |
              
  | 
            
               I pp ≤ 0.5 of max. output current  | 
          |
              
  | 
            
               0... 100 s in steps of 0.1 s, factory-set to 2 s  | 
          |
              
  | 
            
               3.55 ... 23 mA  | 
          |
              
  | 
            
               adjustable within limits: 
  | 
          |
| 
               Load  | 
            ||
              
  | 
            
               
                R
                B ≤ (UH - 10.5 V)/0.023 A in Ω,  | 
          |
              
  | 
            ||
              
  | 
            
               R B = 230 ... 1100 Ω  | 
          |
              
  | 
            
               R B = 230 ... 500 Ω  | 
          |
| 
               Characteristic curve  | 
            
               Linearly rising, linearly falling, square rooted characteristic rising, bidirectional square rooted characteristic and user-specific  | 
          |
| 
               Measuring accuracy  | 
            ||
| 
               Reference conditions (in accordance with IEC 60770-1)  | 
            
              
  | 
          |
              
  | 
          ||
| 
               Total accuracy   | 
            ||
| 
               Linear characteristic  | 
            ||
              
  | 
            
               ≤ 0,09 %  | 
          |
              
  | 
            
               ≤ 0,11 %  | 
          |
| 
               Square-rooted characteristic  | 
            ||
              
  | 
            ||
              
  | 
            
               ≤ 0,09 %  | 
          |
              
  | 
            
               ≤ 0,11 %  | 
          |
              
  | 
            ||
              
  | 
            
               ≤ 0,18 %  | 
          |
              
  | 
            
               ≤ 0,22 %  | 
          |
| 
               Conformity error at limit setting incl. hysteresis and reproducibility  | 
            ||
| 
               Linear characteristic  | 
            ||
              
  | 
            
               ≤ 0,04 %  | 
          |
              
  | 
            
               (0,003 . r + 0.01) %  | 
          |
| 
               Square-rooted characteristic  | 
            ||
              
  | 
            ||
              
  | 
            
               ≤ 0,04 %  | 
          |
              
  | 
            
               (0,003 . r + 0.01) %  | 
          |
              
  | 
            ||
              
  | 
            
               ≤ 0,08 %  | 
          |
              
  | 
            
               (r + 0.02 . 0,06) %  | 
          |
| 
               Influence of ambient temperature per 28 °C  | 
            
               (0,006 . r + 0.01) % /28%  | 
          |
| 
               Influence of static pressure  | 
            ||
              
  | 
            
               ≤ 0.005 % per 70 bar  | 
          |
              
  | 
            
               ≤ 0.03 % per 70 bar  | 
          |
| 
               Step response time T63 without electrical damping  | 
            
               ≤ 90 ms  | 
          |
| 
               Long-term stability  | 
            
               ≤ 0.1 · ) % per 5 years ≤ 0.15 · ) % per 10 years  | 
          |
| 
               Influence of power supply  | 
            
               ≤ 0.005 ... 1 V  | 
          |
| 
               Rated conditions  | 
            
               
  | 
          |
| 
               Mounting position  | 
            
               Any  | 
          |
| 
               Ambient conditions  | 
            ||
              
  | 
            ||
              
  | 
            
               -40 ... +85 °C (-40 ... +185 °F)  | 
          |
              
  | 
            
               -20 ... +85 °C (-4 ... +185 °F)  | 
          |
              
  | 
            
               -50 ... +90 °C (-58 ... +194 °F)  | 
          |
| 
               Climatic class  | 
            ||
              
  | 
            
               Relative humidity 0 … 100 % (condensation permissible)  | 
          |
| 
               Degree of protection (to EN 60529)  | 
            
               IP66/IP68 (with corresponding cable gland)  | 
          |
| 
               Electromagnetic Compatibility  | 
            ||
              
  | 
            
               Acc. to EN 61326 and NAMUR NE 21  | 
          |
| 
               Permissible pressures  | 
            
               According to 97/23/EC pressure equipment directive  | 
          |
| 
               Temperature of medium  | 
            ||
              
  | 
            
               -40 ... +125 °C (-40 ... +257 °F)  | 
          |
|   | 
            
               (Notes that the process flanges will not admit a flow of medium of temperature > 100 °C.)  | 
          |
| 
               Design  | 
            ||
| 
               Weight (without options)  | 
            
               Approx. 3,3 kg (7.3 lb)  | 
          |
| 
               Material of parts in contact with the medium  | 
            ||
              
  | 
            
               Stainless steel, mat. no. 1.4404/316L  | 
          |
              
  | 
            
              
  | 
          |
              
  | 
            
               Standard: Viton (FKM (FPM))  | 
          |
| 
               Material of parts not in contact with media  | 
            ||
| 
               Electronics housing  | 
            
              
  | 
          |
| 
               Process connection screws  | 
            
               Stainless steel  | 
          |
| 
               Mounting bracket  | 
            
               Steel or stainless steel  | 
          |
| 
               Measuring cell filling  | 
            
               Silicone oil  | 
          |
| 
               Process connection  | 
            
               ¼-18 NPT female thread and flange connection with M10 to DIN 19213 or 7/16-20 UNF mounting thread to EN 61518  | 
          |
| 
               Electrical connection  | 
            
              
  | 
          |
| 
               Displays and controls  | 
            ||
| 
               Keys  | 
            
               3 for local programming directly on transmitter  | 
          |
| 
               Digital display  | 
            
              
  | 
          |
| 
               Auxiliary power supply  | 
            ||
| 
               Terminal voltage on transmitter  | 
            
              
  | 
          |
| 
               Separate power supply  | 
            ||
| 
               Certificates and approvals  | 
            ||
| 
               Classification according to PED 97/23/EC  | 
            ||
              
  | 
            
               For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice)  | 
          |
| 
               Explosion protection  | 
            ||
| 
               Explosion protection for Europe (to ATEX)  | 
            ||
              
  | 
            
               PTB 09 ATEX 2004 X  | 
          |
              
  | 
            
               Ex II 1/2 G Ex ia/ib IIC T4  | 
          |
              
  | 
            
               -40 ... +85 °C (-40 ... +185 °F)  | 
          |
              
  | 
            
               To certified intrinsically-safe circuits with peak values:   | 
          |
              
  | 
            
               Li = 400µH  | 
          |
              
  | 
            
               Ci = 6 nF  | 
          |
              
  | 
            
               BVS 09 ATEX E 027  | 
          |
              
  | 
            
               Ex II 1/2 G Ex d IIC T4/T6  | 
          |
              
  | 
            
               -40 ... +85 °C (-40 ... +185 °F) temperature class T4;  | 
          |
              
  | 
            
               To circuits with values: Um = DC 10.5 ... 45 V  | 
          |
              
  | 
            
               PTB 09 ATEX 2004 X  | 
          |
              
  | 
            
               Ex II 1 D Ex iaD 20 T 120 °C  | 
          |
              
  | 
            
               -40 ... +85 °C (-40 ... +185 °F)  | 
          |
              
  | 
            
               120 °C (248 °F)  | 
          |
              
  | 
            
               To certified intrinsically-safe circuits with peak values:   | 
          |
              
  | 
            
               Li = 400µH  | 
          |
              
  | 
            
               Ci = 6 nF  | 
          |
              
  | 
            
               BVS 09 ATEX E 027  | 
          |
              
  | 
            
               Ex II 2 D IP65 T 120 °C  | 
          |
              
  | 
            
               To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W  | 
          |
              
  | 
            
               PTB 09 ATEX 2004 X  | 
          |
              
  | 
            
               Ex II 3 G Ex nA II T4/T6  | 
          |
              
  | 
            
               Um = 45 V DC  | 
          |
              
  | 
            
               Ui = 45 V  | 
          |
              
  | 
            
               Li = 400µH  | 
          |
              
  | 
            
               Ci = 6 nF  | 
          |
| 
               Explosion protection for USA (to FM)  | 
            ||
| 
               Certificate of Compliance  | 
            
               No. 3033013  | 
          |
              
  | 
            
               XP CL I, DIV 1, GP ABCDEFG T4 / T6  CL I, Zone 0, AEx ia IIC T4  | 
          |
              
  | 
            
               Ta = T4: -40 ... +85 °C (-40 ... +185 °F)  | 
          |
              
  | 
            
               According to "control drawing":  | 
          |
              
  | 
            
               NI CL I, DIV2, GP ABCD T4/T6  | 
          |
              
  | 
            
               Ta = T4: -40 ... +85 °C (-40 ... +185 °F)  | 
          |
              
  | 
            
               According to "control drawing":  | 
          |
| 
               Explosion protection for Canada (to C CSA US )  | 
            ||
| 
               Certificate of Compliance  | 
            
               No. 2280963  | 
          |
              
  | 
            
               CL I, DIV 1, GP ABCD T4 /T6;   | 
          |
              
  | 
            
               Ta = T4: -40 ... +85 °C (-40 ... +185 °F)  | 
          |
              
  | 
            
               According to "control drawing":  | 
          |
              
  | 
            
               CL I, Ex ia/Ex ib IIC, T4  | 
          |
              
  | 
            
               Ta = T4: -40 ... +85 °C (-40 ... +185 °F)  | 
          |
              
  | 
            
               Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω , Li = 400 µH, Ci = 6 nF  | 
          |
              
  | 
            
               CL I, DIV2, GP ABCD T4/T6  | 
          |
              
  | 
            
               Ta = T4: -40 ... +85 °C (-40 ... +185 °F)  | 
          |
              
  | 
            
               According to "control drawing":  | 
          |
              
  | 
            
               According to "control drawing":  | 
          |
| 
               HART communication  | 
            |
|---|---|
| 
               Load with connection of  | 
            |
              
  | 
            
               R B = 230 ... 1100 Ω  | 
          
              
  | 
            
               R B = 230 ... 500 Ω  | 
          
| 
               Cable  | 
            
               2 wire shielded: ≤ 3.0 km (1.86 miles),  | 
          
| 
               Protocol  | 
            
               HART Version 6.0  | 
          
| 
               PC/laptop requirements  | 
            
               IBM compatible, RAM > 32 Mb,  | 
          
| 
               Software for computer  | 
            
               SIMATIC PDM 6.0  | 
          